Search
Publication:
abstract
AIM:
To describe a surgical technique to treat colostomy prolapse as a day case procedure with the patient under sedation and analgesia.
METHOD:
A 60-mm GIA Universal Stapler is inserted into the lumen of the prolapsed colon at right angles to the contour of the abdominal wall. Several firings are then made to completely divide the prolapsed colon. The instrument is then placed parallel to the skin to remove the prolapsed portion leaving 1-2 cm of bowel above the level of the skin.
RESULTS:
Two patients underwent the procedure. The operation times were 30 and 13 min. Both took oral liquids 2 h after surgery and solids 2 h later. They were discharged at 24 and 4 h after surgery, respectively. No postoperative pain was reported in either case. At 14 and 6 months of follow-up there has been no recurrence.
CONCLUSION:
stapling treatment of prolapsed colostomies has the advantage of being an extra-abdominal procedure. It is performed under sedation and analgesia, the operation time is very short, recovery to normal life is rapid and there is less likelihood of complications by avoiding a laparotomy.
© 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.
Related Articles
Correction of end colostomy prolapse using a curved surgical stapler, performed under sedation.
Tech Coloproctol. 2010
Correction of end colostomy prolapse using a curved surgical stapler, performed under sedation.
Ferguson HJ, Bhalerao S. Tech Coloproctol. 2010 Jun; 14(2):165-7. Epub 2010 Mar 23.
A novel, easy, and safe technique to repair a stoma prolapse using a surgical stapling device.
Dig Surg. 2005
A novel, easy, and safe technique to repair a stoma prolapse using a surgical stapling device.
Hata F, Kitagawa S, Nishimori H, Furuhata T, Tsuruma T, Ezoe E, Ishiyama G, Ohno K, Fukui R, Yanai Y, et al. Dig Surg. 2005; 22(5):306-9; discussion 310. Epub 2005 Sep 28.
[Repair of mucosa stomal prolapse with circular stapler. Technical note].
Chir Ital. 2003
[Repair of mucosa stomal prolapse with circular stapler. Technical note].
Trentin G, De Simone P, Mainente P, Agresta F, Bedin N. Chir Ital. 2003 Jan-Feb; 55(1):141-3.
Review Rectal perforation, retropneumoperitoneum, and pneumomediastinum after stapling procedure for prolapsed hemorrhoids: report of a case and subsequent considerations.
Dis Colon Rectum. 2002
Review Rectal perforation, retropneumoperitoneum, and pneumomediastinum after stapling procedure for prolapsed hemorrhoids: report of a case and subsequent considerations.
Ripetti V, Caricato M, Arullani A. Dis Colon Rectum. 2002 Feb; 45(2):268-70.
Review Results of the double stapling procedure in pelvic surgery.
World J Surg. 1992
Review Results of the double stapling procedure in pelvic surgery.
Griffen FD, Knight CD Sr, Knight CD Jr. World J Surg. 1992 Sep-Oct; 16(5):866-71.